How to Solve OBDSTAR P50 with Godiag OBD2 Jumper Read Data Failure?

One customer used Godiag Full Protocol OBD2 Jumper to work with OBDSTAR P50 to reset airbag on Mazda, it didn’t read data and appeared communication error. But he used the P004 Jumper and adapter that came with OBDStar can read data successfully. Is there something wrong with Godiag Jumper? How to solve it?

obdstar p50 and godiag jumper read data failure solution 1 obdstar p50 and godiag jumper read data failure solution 2 obdstar p50 and godiag jumper read data failure solution 3 obdstar p50 and godiag jumper read data failure solution 4

 

Here is the solution.

Just connect CAN H and CAN L cable of Godiag OBD2 jumper via one electrical resistance (120 ohm resistor), then the problem will be solved.

The Electrical resistances can be found in the Godiag Breakout Tricore Cable package. There are three in all.

obdstar p50 and godiag jumper read data failure solution 5 obdstar p50 and godiag jumper read data failure solution 6

 

Finally, the customer gave feedback below.

Thanks so much! I tried it and worked fine!

obdstar p50 and godiag jumper read data failure solution 7

 